EMS 7500 (Digital)

Our EMS 7500 Digital unit is one of the most technologically advanced EMS units available today. With so many features, yet so easy to use, the EMS 7500 makes a good fit for almost any patient. The digital controls allow you to have more control over the pulse strength & frequency, allowing your patients to find that perfect setting that is both comfortable and effective.

For patients who want a unit that’s reliable, durable and versatile the EMS 7500 makes the perfect choice. Each package includes 1 EMS 7500 Digital unit with LIFETIME WARRANTY, 1-9 volt battery, Starter packs of electrodes and lead wires. Everything you need to start relieving the pain immediately. AC adapters are available upon request.

WARNING: This is a Class II Medical device and Federal law Restricts this device to sale by or on the order of a Physician.

Detailed Description

    • Channels: Dual Channel, isolated between channels
    • Pulse Amplitude: Adjustable, 0-100 mA peak into 500 ohm load each channel.
    • Voltage: 0 – 50V (Load: 500 ohm)
    • Pulse Rate: Adjustable, from 2 to 150 Hz, 1 Hz/step
    • Pulse Width: Adjustable, from 50 to 300 microseconds, 10uS/step
    • Wave Form: Asymmetrical Bi-Phasic Square Pulse
    • On Time: Adjustable, 2~90 seconds , 1 Sec./ step
    • Off Time: Adjustable, 2~90 seconds , 1 Sec./ step
    • Ramp Time: Adjustable, 1~8 seconds, 1 Sec./ step, The “On” time will increase and decrease in the setting value.
    • 3 Modes: Constant ,Synchronous, Alternate
    • Constant: stimulation based on setting value. Only pulse width, pulse rate and timer are adjustable in this mode. “Constant” is equal to the “Normal” mode of a TENS unit.
    • Synchronous: Stimulation of both channels occurs synchronously. The “ON” time including “Ramp Up” and “Ramp Down” time. Therefore, the setting of ON Time should be no less than two times of the “Ramp” time in this mode. ON TIME ? ?Ramp up + Ramp down
    • Alternate: The stimulation of the CH2 will occur after the 1st contraction of CH1 is completed. In this mode, the setting of ON Time should be no less than two times of the “Ramp” time. The OFF Time should be equal or more than the ON Time. ON TIME ? ?Ramp up + Ramp down OFF TIME ~ON~.
    • Patient Compliance Meter: This unit can store 60 sets of operation records. Total recorded time is 999 hours.
    • Timer: Adjustable, from 5 to 60 minutes or Continuous. Adjustable in 5 minutes each step. Treatment time countdown automatically.
    • Lifetime Warranty
    • System Includes: Stimulator, Lead Wires, 2 packages of high quality Self-Adhesive Electrodes, 9V Battery, Hard Plastic Carrying Case, Instruction Booklet.